Techniques Appear To Lower Radiation Exposure From Cardiac Scans Without Impairing Image Quality

Date:
June 12, 2009
Source:
JAMA and Archives Journals
Summary:
An intervention that includes techniques to reduce the amount of radiation from cardiac computed tomography angiography (scanning used to diagnose coronary artery disease) was associated with decreasing patient exposure to radiation without significantly changing the quality of the images, according to a new study.

An intervention that includes techniques to reduce the amount of radiation from cardiac computed tomography angiography (scanning used to diagnose coronary artery disease) was associated with decreasing patient exposure to radiation without significantly changing the quality of the images, according to a new study.

Related Articles


Coronary artery disease remains the most frequent cause of death and disability in the developed world and rates are increasing among developing nations. "As the population at risk has increased, national health care systems are under financial pressure to deliver cost-effective diagnosis and risk stratification of symptomatic patients suspected of having coronary ischemia. Noninvasive multislice cardiac computed tomography angiography (CCTA) has emerged since 2000 as a new diagnostic test with the potential to efficiently address this challenge," the authors write. Results from multiple studies suggest that CCTA may definitively exclude the diagnosis of coronary artery disease in a substantial proportion of appropriately selected patients, however radiation dose from this procedure is of concern.

Gilbert L. Raff, M.D., of William Beaumont Hospital, Royal Oak, Mich., and colleagues conducted a study to determine whether implementation of an intervention to improve the technique for scan acquisition would be associated with a reduction in the estimated radiation dose from CCTA and what would be the associated effects on image quality. The study included 4,995 patients undergoing CCTA for suspected coronary artery disease at 15 hospital imaging centers, which included small community hospitals and large academic centers; 4,862 patients (97.3 percent) had complete radiation data for analysis. The techniques to reduce radiation dose included minimized scan range, heart rate reduction, electrocardiographic-gated tube current modulation, and reduced tube voltage in suitable patients.

The researchers found that compared with the control period, patients' median (midpoint) estimated radiation dose in the follow-up period was reduced by 53.3 percent. An increase in the number of patients receiving the target dose below a certain level (compared with the control period) was achieved at all sites. The increase in the proportion of those reaching the target dose was greatest at low-volume sites (less than 30 scans per month).

"Importantly, despite the reduction in the radiation doses, there were no significant changes during the control period compared with follow-up period in median image quality rating or the proportion of diagnostic-quality scans (554/620 patients [89 percent] in the control period vs. 769/835 patients [92 percent] in the follow-up period)," the authors write.

The most powerful factors associated with achievement of the target radiation dose were the use of lower tube voltage, which increased from 13 percent to 43 percent of cases, and a site study volume of more than 30 scans per month. Among patient-related variables, reduction in heart rate demonstrated a strong positive association with a decreased radiation dose.

"Baseline data obtained in this study support the concern that CCTA testing may result in relatively high radiation doses, but the rapid improvement in radiation dose in the first 3 intervention months demonstrates how use of existing technology and technical methods is associated with dramatically reduced dosages. The dose-reduction program involved an educational aspect at every level in the imaging process. Without a feedback loop of regular dose measurements and reports, similar monitoring of patient preparation, and appropriate imaging protocols and resultant image quality, there would neither be the opportunity to detect dose elevations nor the ability to improve practice," the researchers write.

"The importance of radiation-reduction techniques must be emphasized during physician and technologist training and physicians should demonstrate technical mastery of these methods before certification to oversee CCTA scanning."


Story Source:

The above story is based on materials provided by JAMA and Archives Journals. Note: Materials may be edited for content and length.


Journal Reference:

  1. Gilbert L. Raff; Kavitha M. Chinnaiyan; David A. Share; Tauqir Y. Goraya; Ella A. Kazerooni; Mauro Moscucci; Ralph E. Gentry; Aiden Abidov; for the Advanced Cardiovascular Imaging Consortium Co-Investigators. Radiation Dose From Cardiac Computed Tomography Before and After Implementation of Radiation Dose%u2013Reduction Techniques. JAMA, 2009;301(22):2340-2348 [link]

Cite This Page:

JAMA and Archives Journals. "Techniques Appear To Lower Radiation Exposure From Cardiac Scans Without Impairing Image Quality." ScienceDaily. ScienceDaily, 12 June 2009. <www.sciencedaily.com/releases/2009/06/090609215937.htm>.
JAMA and Archives Journals. (2009, June 12). Techniques Appear To Lower Radiation Exposure From Cardiac Scans Without Impairing Image Quality. ScienceDaily. Retrieved October 30, 2014 from www.sciencedaily.com/releases/2009/06/090609215937.htm
JAMA and Archives Journals. "Techniques Appear To Lower Radiation Exposure From Cardiac Scans Without Impairing Image Quality." ScienceDaily. www.sciencedaily.com/releases/2009/06/090609215937.htm (accessed October 30, 2014).

Share This



More Health & Medicine News

Thursday, October 30, 2014

Featured Research

from universities, journals, and other organizations


Featured Videos

from AP, Reuters, AFP, and other news services

Mind-Controlled Prosthetic Arm Restores Amputee Dexterity

Mind-Controlled Prosthetic Arm Restores Amputee Dexterity

Reuters - Innovations Video Online (Oct. 29, 2014) A Swedish amputee who became the first person to ever receive a brain controlled prosthetic arm is able to manipulate and handle delicate objects with an unprecedented level of dexterity. The device is connected directly to his bone, nerves and muscles, giving him the ability to control it with his thoughts. Matthew Stock reports. Video provided by Reuters
Powered by NewsLook.com
Google To Use Nanoparticles, Wearables To Detect Disease

Google To Use Nanoparticles, Wearables To Detect Disease

Newsy (Oct. 29, 2014) Google X wants to improve modern medicine with nanoparticles and a wearable device. It's all an attempt to tackle disease detection and prevention. Video provided by Newsy
Powered by NewsLook.com
Can Drinking Milk Lead To Early Death?

Can Drinking Milk Lead To Early Death?

Newsy (Oct. 29, 2014) Researchers in Sweden released a study showing heavy milk drinkers face an increased mortality risk from a variety of causes. Video provided by Newsy
Powered by NewsLook.com
Obama: The US Will Not 'run and Hide' From Ebola

Obama: The US Will Not 'run and Hide' From Ebola

AP (Oct. 29, 2014) Surrounded by health care workers in the White House East Room, President Barack Obama said the U.S. will likely see additional Ebola cases in the weeks ahead. But he said the nation can't seal itself off in the fight against the disease. (Oct. 29) Video provided by AP
Powered by NewsLook.com

Search ScienceDaily

Number of stories in archives: 140,361

Find with keyword(s):
Enter a keyword or phrase to search ScienceDaily for related topics and research stories.

Save/Print:
Share:

Breaking News:

Strange & Offbeat Stories


Health & Medicine

Mind & Brain

Living & Well

In Other News

... from NewsDaily.com

Science News

Health News

    Environment News

    Technology News



    Save/Print:
    Share:

    Free Subscriptions


    Get the latest science news with ScienceDaily's free email newsletters, updated daily and weekly. Or view hourly updated newsfeeds in your RSS reader:

    Get Social & Mobile


    Keep up to date with the latest news from ScienceDaily via social networks and mobile apps:

    Have Feedback?


    Tell us what you think of ScienceDaily -- we welcome both positive and negative comments. Have any problems using the site? Questions?
    Mobile: iPhone Android Web
    Follow: Facebook Twitter Google+
    Subscribe: RSS Feeds Email Newsletters
    Latest Headlines Health & Medicine Mind & Brain Space & Time Matter & Energy Computers & Math Plants & Animals Earth & Climate Fossils & Ruins