Science News

Electronic Alerts About Abnormal Imaging Test Results Do Not Always Result In Timely Follow-Up

ScienceDaily (Sep. 28, 2009) — Abnormal results on outpatient imaging tests sometimes may not receive timely follow-up even when clinicians receive and read results in an advanced, integrated electronic medical record system, according to a report in the September 28 issue of Archives of Internal Medicine, one of the JAMA/Archives journals.

"Communication breakdown is consistently identified as a preventable factor in studies of adverse events and a significant contributor to outpatient diagnostic errors from a lack of follow-up of abnormal test results," the authors write as background information in the article. The high volume and number of transitions between clinicians in outpatient care makes timely communication particularly challenging. For instance, a primary care physician may refer a patient with respiratory symptoms to undergo several laboratory and imaging tests and a pulmonary consultation. Any abnormal findings, such as a lung mass, would need to be communicated quickly and effectively to all clinicians involved in treating the patient.

Some health care systems, including the Department of Veterans Affairs, use electronic communication with alerts to notify clinicians who order imaging tests about critical abnormal results—an approach that may have advantages over a paper-based reporting system. "However, effective communication involves more than just information transfer—it requires a response from the recipient, such as taking follow-up action and acknowledging receipt of the information to the sender," the authors write.

Hardeep Singh, M.D., M.P.H., of Michael E. DeBakey Veterans Affairs Medical Center and Baylor College of Medicine, Houston, studied critical imaging alert notifications in the outpatient setting of one Department of Veterans Affairs facility between November 2007 and June 2008. The researchers used tracking software to determine whether alerts about abnormal test results were read within two weeks, then reviewed medical records and contacted health care practitioners to determine whether timely follow-up actions (such as ordering a follow-up test or consultation) were taken within four weeks of the alert transmission.

Of 123,638 imaging tests (including X-rays, computed tomographic [CT] scans, magnetic resonance imaging [MRI] and mammograms) performed during the study period, results from 1,196 (0.97 percent) generated alerts to the ordering clinician. Of these alerts, 217 (18.1 percent) were not acknowledged. Alerts were more likely to be unacknowledged if the ordering clinician was a trainee or if an alert was sent to more than one clinician (for example, when the ordering clinician was not the patient's primary care physician, and alerts were sent to both the specialist and the patient's regular physician).

Timely follow-up of abnormal results did not occur following 92 (7.7 percent) of all alerts, including 7.3 percent of alerts that were acknowledged and 9.7 percent of alerts that were unacknowledged. This follow-up was also less likely to occur when more than one clinician received the alert, but more likely to occur when a radiologist also communicated concerns about the results verbally, either by phone or in person. "Nearly all abnormal test results lacking timely follow-up at four weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment," the authors write.

"Our findings suggest that an electronic medical record that facilitates transmission and availability of critical imaging results to the health care provider through either automated notification or direct access of primary report does not eliminate the problem of missed test results even when one or more health care providers read the results," they conclude. "Therefore, even in the best of information systems that contain advanced notification features, patients with abnormal imaging results are vulnerable to 'falling through the cracks.' This underscores the need for a multidisciplinary approach involving human-computer interaction and informatics to complement the benefits achieved by automated notification and the need for continuous monitoring procedures to ensure follow-up even when health care providers 'acknowledge,' i.e., read abnormal results."

Email or share this story:
| More

Story Source:

Adapted from materials provided by JAMA and Archives Journals.

Journal Reference:

  1. Hardeep Singh; Eric J. Thomas; Shrinidi Mani; Dean Sittig; Harvinder Arora; Donna Espadas; Myrna M. Khan; Laura A. Petersen. Timely Follow-up of Abnormal Diagnostic Imaging Test Results in an Outpatient Setting: Are Electronic Medical Records Achieving Their Potential? Arch Intern Med, 2009; 169 (17): 1578-1586 [link]
APA

MLA

Note: If no author is given, the source is cited instead.

Search ScienceDaily

Number of stories in archives: 78,132

Find with keyword(s):
 
Enter a keyword or phrase to search ScienceDaily's archives for related news topics,
the latest news stories, reference articles, science videos, images, and books.

 

Science Video News


Voting Machines: Make Your Vote Count!

Human-factors engineers, along with the National Institute of Standards and Technology (NIST) have developed a rigorous, standardized test for all. ...  > full story

Breaking News

... from NewsDaily.com

In Other News ...

Copyright Reuters 2008. See Restrictions.

Free Subscriptions

... from ScienceDaily

Get the latest science news with our free email newsletters, updated daily and weekly. Or view hourly updated newsfeeds in your RSS reader:

Feedback

... we want to hear from you!

Tell us what you think of the new ScienceDaily -- we welcome both positive and negative comments. Have any problems using the site? Questions?
Post this page to your favorite social bookmarking site:
close
Include this item in your blog or web site:
close
Cite this article in your essay, paper, or report:
close
Email this page's link to a friend or colleague:
close