Science News

... from universities, journals, and other research organizations

New Fluorescent Dyes Highlight Neuronal Activity

ScienceDaily (Jan. 25, 2012) — Researchers at the University of California, San Diego School of Medicine have created a new generation of fast-acting fluorescent dyes that optically highlight electrical activity in neuronal membranes. The work is published in this week's online Early Edition of the Proceedings of the National Academy of Sciences.

The ability to visualize these small, fast-changing voltage differences between the interior and exterior of neurons -- known as transmembrane potential -- is considered a powerful method for deciphering how brain cells function and interact.

However, current monitoring methods fall short, said the study's first author Evan W. Miller, a post-doctoral researcher in the lab of Roger Tsien, PhD, Howard Hughes Medical Institute investigator, UC San Diego professor of pharmacology, chemistry and biochemistry and 2008 Nobel Prize co-winner in chemistry for his work on green fluorescent protein.

"The most common method right now monitors the movement of calcium ions into the cell," said Miller. "It provides some broad indication, but it's an indirect measurement that misses activity we see when directly measuring voltage changes."

The new method employs dyes that penetrate only the membrane of neurons, either in in vitro cells cultured with the dye or, for this study, taken up by neurons in a living leech model. When the dyed cells are exposed to light, neuronal firing causes the dye momentarily to glow more brightly, a flash that can be captured with a high-speed camera.

"One of the tradeoffs with using voltage-sensing dyes in the past is that when they were reasonably sensitive to voltage changes, they were slow compared to the actual physiological events," said Miller. "The new dye gives big signals but is much faster and doesn't perturb the neurons. We essentially see no lag time between the optical signal and electrodes (used to double-check neuronal activity)."

The new method provides a wider view of neuronal activity, said Miller. More importantly, it makes it possible for neuroscientists to do accurate, single trial experiments. "Right now, you have to repeat experiments with cells, and then average the results, which is physiologically less relevant and meaningful."

For Tsien, the new dyes address a career-long challenge.

"These results are the first demonstration of a new mechanism to sense membrane voltage, which is particularly satisfying to me because this was the first problem I started working on as a graduate student in 1972, with little success back then," said Tsien. "Later, we devised indirect solutions such as calcium imaging or dyes that gave big but slow responses to voltage. These techniques have been very useful in other areas of biology or in drug screening, but didn't properly solve the original problem. I think we are finally on the right track, four decades later."

Funding for this research came, in part, from the Howard Hughes Medical Institute, the National Institutes of Health, including the National Institute of Neurological Disorders and Stroke and the National Institute of Biomedical Imaging and Bioengineering.

Co-authors are John Y. Lin, Department of Pharmacology, UC San Diego; E. Paxon Frady, Neurosciences Graduate Group, UC San Diego; Paul A. Steinbach, Department of Pharmacology, UC San Diego and Howard Hughes Medical Institute; William B. Kristan, Jr., Division of Biological Sciences, UC San Diego.

Share this story on Facebook, Twitter, and Google:

Other social bookmarking and sharing tools:

|

Story Source:

The above story is reprinted from materials provided by University of California, San Diego Health Sciences, via Newswise.

Note: Materials may be edited for content and length. For further information, please contact the source cited above.


Journal Reference:

  1. E. W. Miller, J. Y. Lin, E. P. Frady, P. A. Steinbach, W. B. Kristan, R. Y. Tsien. Optically monitoring voltage in neurons by photo-induced electron transfer through molecular wires. Proceedings of the National Academy of Sciences, 2012; DOI: 10.1073/pnas.1120694109
APA

MLA

Note: If no author is given, the source is cited instead.

Disclaimer: This article is not intended to provide medical advice, diagnosis or treatment. Views expressed here do not necessarily reflect those of ScienceDaily or its staff.

Search ScienceDaily

Number of stories in archives: 118,843

Find with keyword(s):
 
Enter a keyword or phrase to search ScienceDaily's archives for related news topics,
the latest news stories, reference articles, science videos, images, and books.

 
  more breaking science news

Social Networks


Recommend and share this story on Facebook, Twitter, and Google +1:
Other bookmarking and sharing tools:
|

Breaking News

... from NewsDaily.com

In Other News ...

Copyright Reuters 2008. See Restrictions.

Free Subscriptions

... from ScienceDaily

Get the latest science news with our free email newsletters, updated daily and weekly. Or view hourly updated newsfeeds in your RSS reader:

Feedback

... we want to hear from you!

Tell us what you think of ScienceDaily -- we welcome both positive and negative comments. Have any problems using the site? Questions?

Post this page to your favorite social bookmarking site:
Include this item in your blog or web site:
Cite this article in your essay, paper, or report:
Email this page's link to a friend or colleague: