Featured Research

from universities, journals, and other organizations

Replacing hydrogen in fluorescent dyes improves detection ability, stability and shelf life

Date:
July 20, 2010
Source:
Georgia Institute of Technology
Summary:
By swapping out a hydrogen atom for an isotope twice as heavy, researchers have increased the shelf life and detection ability of fluorescent probes that are essential to studying a variety of inflammatory diseases, including cancer and atherosclerosis.

Coulter Department of Biomedical Engineering postdoctoral fellows Seungjun Lee and Kousik Kundu and associate professor Niren Murthy (left-right) discuss their experimental results, which show that by replacing a hydrogen atom with a deuterium atom during the synthesis of fluorescent probes, they increased the stability and shelf life of the dyes, and also improved their ability to detect smaller concentrations of reactive oxygen species.
Credit: Georgia Tech Photo: Gary Meek

By swapping out one specific hydrogen atom for an isotope twice as heavy, researchers have increased the shelf life and detection ability of fluorescent probes that are essential to studying a variety of inflammatory diseases, including cancer and atherosclerosis. The probes detect and measure reactive oxygen species, which play an important role in disease processes.

"By replacing a hydrogen atom with a deuterium atom during the synthesis of several fluorescent probes, we increased the stability and shelf life of the dyes, and also improved their ability to detect smaller concentrations of reactive oxygen species," said Niren Murthy, associate professor in the Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech and Emory University.

Deuterium is an isotope of hydrogen that has a single proton and single neutron in its nucleus. Its atomic weight is therefore twice that of the much more common hydrogen atom, which lacks a neutron.

When Murthy and Coulter Department postdoctoral fellow Kousik Kundu designed and synthesized various fluorescent probes with deuterium instead of hydrogen, the dyes were not as susceptible to spontaneous degradation by air and light as their hydrogen counterparts, which made them significantly more accurate at detecting reactive oxygen species in cells and animals. The researchers studied probes that included dihydroethidium (DHE) -- the current "gold standard" for imaging reactive oxygen species -- and hydrocyanines.

Details of the research were published in the early view of the journal Angewandte Chemie International on July 20. The work was sponsored by the National Institutes of Health and the National Science Foundation.

The study showed that while the standard fluorescent probe DHE was 60 percent oxidized by air and light after 10 days in storage, its deuterium counterpart was only 20 percent oxidized during that same time. These findings could have significant implications for companies that produce fluorescent probes and other compounds, according to Murthy, because commercializing and shipping the modified probes will be easier.

Another advantage for scientists using deuterium-containing fluorescent probes is that after reacting with reactive oxygen species, the probes produce the same fluorescent dye that their hydrogen counterparts produce.

"This is important from a practical standpoint because scientists have developed protocols with DHE and other fluorescent probes that they will be able to continue using by simply substituting the more stable and accurate deuterated version into the assay," explained Murthy.

Fluorescent probes detect reactive oxygen species by undergoing a chemical process called amine oxidation. The mechanism of amine oxidation for reactions involving reactive oxygen species differs significantly from reactions involving air and light. In addition, reactions with deuterium-containing probes occur at a much slower rate because deuterium is a heavier atom.

Murthy and Kundu decided to use these mechanistic and kinetic differences to selectively slow the oxidation of the fluorescent probes by air and light while maintaining their reactivity with cellular reactive oxygen species. To test the selective suppression of oxidation, the researchers examined the kinetic isotope effect -- a value that measures the ratio of the rate of a chemical reaction with hydrogen compared to the same reaction with deuterium to air and radical oxidation.

They investigated the ability of the deuterium-containing probes to compete with a common enzyme for superoxide -- a reactive oxygen species that is a form of molecular oxygen with one extra electron. The researchers found that the probes' oxidation mechanism with superoxide was different than for spontaneous oxidation because the two reactions exhibited different values for the kinetic isotope effect. Kinetic isotope effect values for spontaneous oxidation ranged from 3.7-4.7, whereas values for superoxide oxidation were between 2.5-2.8 for many different types of deuterium-containing fluorescent dyes, including DHE.

"This was the key experiment that demonstrated that there was a much larger difference in the way the hydrogen and deuterium compounds reacted to spontaneous oxidation than how they dealt with oxidation by a reactive oxygen species," explained Murthy.

Murthy's collaborators W. Robert Taylor and Sarah Knight tested the ability of both types of dyes to detect reactive oxygen species inside cells. Since the deuterium-containing probes were less affected by air and light and background fluorescence was suppressed, the researchers found that the dyes more accurately detected small amounts of reactive oxygen species. Knight is an Emory University postdoctoral fellow and Taylor is a professor in the Coulter Department, the director of Emory's Division of Cardiology, and a member of the Atlanta VA Medical Center's Division of Cardiology.

Following the cellular experiments, Knight and Coulter Department postdoctoral fellow Seungjun Lee investigated whether the kinetic isotope effect would similarly improve the ability of H-Cy7 -- a hydrocyanine dye developed by Murthy -- to detect radical oxidants in vivo. In experiments, the deuterium-containing version of Cy7 generated a 10-fold difference in fluorescence intensity versus control probes compared to only a five-fold difference for the hydrogen probe.

"This new process of replacing hydrogen with deuterium is potentially valuable because the positive results are universal among many different types and classes of probes," explained Murthy. "All of the modified probes generated less background fluorescence, while maintaining high reactivity with reactive oxygen species and generating similar levels of fluorescence in cells and animals stimulated to produce them."

Murthy indicated that although the kinetic isotope effect had been used to improve drug stability, it has never been used to improve probe development.

"Based on our results, we anticipate numerous applications of deuterated radical oxidant probes in biology and an increased application of the kinetic isotope effect in biological probe development," added Murthy.

This project is supported by the National Science Foundation (NSF) (Award Nos. EEC-9731643 and NSF Career BES-0546962) and the National Institutes of Health (NIH) (Award Nos. UO1 HL80711-01, R21 EB006418, RO1 HL096796-01 and RO1 HL090584). The content is solely the responsibility of the principal investigator and does not necessarily represent the official views of the NSF or NIH.


Story Source:

The above story is based on materials provided by Georgia Institute of Technology. Note: Materials may be edited for content and length.


Journal Reference:

  1. Kundu et al. A Significant Improvement of the Efficacy of Radical Oxidant Probes by the Kinetic Isotope Effect. Angewandte Chemie, 2010; DOI: 10.1002/ange.201002228

Cite This Page:

Georgia Institute of Technology. "Replacing hydrogen in fluorescent dyes improves detection ability, stability and shelf life." ScienceDaily. ScienceDaily, 20 July 2010. <www.sciencedaily.com/releases/2010/07/100720123629.htm>.
Georgia Institute of Technology. (2010, July 20). Replacing hydrogen in fluorescent dyes improves detection ability, stability and shelf life. ScienceDaily. Retrieved April 16, 2014 from www.sciencedaily.com/releases/2010/07/100720123629.htm
Georgia Institute of Technology. "Replacing hydrogen in fluorescent dyes improves detection ability, stability and shelf life." ScienceDaily. www.sciencedaily.com/releases/2010/07/100720123629.htm (accessed April 16, 2014).

Share This



More Matter & Energy News

Wednesday, April 16, 2014

Featured Research

from universities, journals, and other organizations


Featured Videos

from AP, Reuters, AFP, and other news services

Google Patents Contact Lens Cameras; Internet Is Wary

Google Patents Contact Lens Cameras; Internet Is Wary

Newsy (Apr. 15, 2014) Google has filed for a patent to develop contact lenses capable of taking photos. The company describes possible benefits to blind people. Video provided by Newsy
Powered by NewsLook.com
The Walking, Talking Oil-Drigging Rig

The Walking, Talking Oil-Drigging Rig

Reuters - Business Video Online (Apr. 15, 2014) Pennsylvania-based Schramm is incorporating modern technology in its next generation oil-drigging rigs, making them smaller, safer and smarter. Ernest Scheyder reports. Video provided by Reuters
Powered by NewsLook.com
Dutch Highway Introduces Glow-In-The-Dark Paint

Dutch Highway Introduces Glow-In-The-Dark Paint

Newsy (Apr. 14, 2014) A Dutch highway has become the first lit by glow-in-the-dark paint — a project aimed at reducing street light use. Video provided by Newsy
Powered by NewsLook.com
Google Buys Drone Maker, Hopes to Connect Rural World

Google Buys Drone Maker, Hopes to Connect Rural World

Newsy (Apr. 14, 2014) Formerly courted by Facebook, Titan Aerospace will become a part of Google's quest to blanket the world in Internet connectivity. Video provided by Newsy
Powered by NewsLook.com

Search ScienceDaily

Number of stories in archives: 140,361

Find with keyword(s):
Enter a keyword or phrase to search ScienceDaily for related topics and research stories.

Save/Print:
Share:

Breaking News:
from the past week

In Other News

... from NewsDaily.com

Science News

Health News

Environment News

Technology News



Save/Print:
Share:

Free Subscriptions


Get the latest science news with ScienceDaily's free email newsletters, updated daily and weekly. Or view hourly updated newsfeeds in your RSS reader:

Get Social & Mobile


Keep up to date with the latest news from ScienceDaily via social networks and mobile apps:

Have Feedback?


Tell us what you think of ScienceDaily -- we welcome both positive and negative comments. Have any problems using the site? Questions?
Mobile: iPhone Android Web
Follow: Facebook Twitter Google+
Subscribe: RSS Feeds Email Newsletters
Latest Headlines Health & Medicine Mind & Brain Space & Time Matter & Energy Computers & Math Plants & Animals Earth & Climate Fossils & Ruins