New! Sign up for our free email newsletter.
Science News
from research organizations

Heart Mapping Technique Safely Guides Catheter Repair Of Arrhythmia

Date:
November 14, 2005
Source:
Johns Hopkins Medical Institutions
Summary:
In experiments with dogs, Johns Hopkins researchers successfully used a 3D map of the heart and sensor-guided catheter to perform cardiac ablation, a mainstay treatment that stops abnormally fast and potentially fatal heartbeats, or arrhythmias.
Share:
FULL STORY

In experiments with dogs, Johns Hopkins researchers successfully used a 3D map of the heart and sensor-guided catheter to perform cardiac ablation, a mainstay treatment that stops abnormally fast and potentially fatal heartbeats, or arrhythmias.

The Hopkins findings, to be presented at the American Heart Association's Scientific Sessions 2005 on Nov. 13 in Dallas, Texas, provided information and technology used by the United States Food and Drug Administration to approve the system in March for testing in humans, now under way.

The Hopkins team created their own 3D models of each heart from images obtained by integrating and superimposing CT and MRI scans. Using an upgraded computer software program known as electro-anatomic mapping, the scientists are able to color-code the heart models' structures.

The scientists safely ablated, or destroyed, tiny areas of diseased heart tissue that facilitate rhythm disturbances, guided only by these anatomically precise, reconstructed 3D map.

During the procedure, a catheter containing a magnetic sensor in its tip is inserted through a vein in the dog's leg, then guided to the heart, where it is used to burn off the small part of heart muscle that gives rise to the errant signaling responsible for the arrhythmia.

A magnetic location pad was placed under the operating table and situated directly beneath the animal's body to detect the position of the catheter and compare it to the computer-generated image of the heart displayed on a screen.

"This is a significant improvement for patient safety and the performance of minimally invasive procedures in the heart," says study senior investigator and cardiologist Timm Dickfeld, M.D., Ph.D., an adjunct assistant professor at The Johns Hopkins University School of Medicine and its Heart Institute. Dickfeld points out that current methods for visualizing the heart, using X-rays and fluoroscopy, are potentially hazardous because they involve radiation and produce only two-dimensional images, which are not as accurate as 3D images.

"Our study proves the effectiveness of 3D mapping in guiding and pinpointing the catheter's tip during a procedure, giving the electrophysiologist a more concrete awareness on the placement of lesions, and it eliminates the need for an X-ray, reducing the amount of radiation exposure for the patient," he adds.

As part of the study, the Hopkins scientists performed catheter ablation in nine dogs who had nearly 50 CT markers, small wafer-like targets that could be seen by a scanner, surgically implanted on the outside of their hearts' muscle wall. The placement of the wafers covered all regions of the heart, especially those where arrhythmia are known to occur. Three-dimensional maps of the hearts, made shortly before the procedure, were then used to guide the catheter to their targets.

After the procedure, analysis of heart tissue showed that the 3D maps worked very well and were extremely precise and safe, Dickfeld says. The range of errors in pinpointing therapy to a lesion was between 1.9 millimeters and 4.9 millimeters, and well within lesion boundaries that average 6 millimeters in diameter.

"A physician really needs precise anatomical information during ablation because one move in the wrong direction could damage healthy heart tissue or puncture the organ," says study lead investigator Jun Dong, M.D., a postdoctoral research fellow at Hopkins. Dong's research will be presented at the meeting as a finalist for the Melvin Judkins Young Clinical Investigator Award. Previous research by Dong and colleagues showed complications like this occur in nearly 5 percent of catheter ablation procedures for atrial fibrillation.

###

Funding for this study, which took three months to complete, was provided by Biosense Webster Inc., of Haifa, Israel, the manufacturer of the electro-anatomic mapping system.


Story Source:

Materials provided by Johns Hopkins Medical Institutions. Note: Content may be edited for style and length.


Cite This Page:

Johns Hopkins Medical Institutions. "Heart Mapping Technique Safely Guides Catheter Repair Of Arrhythmia." ScienceDaily. ScienceDaily, 14 November 2005. <www.sciencedaily.com/releases/2005/11/051114215823.htm>.
Johns Hopkins Medical Institutions. (2005, November 14). Heart Mapping Technique Safely Guides Catheter Repair Of Arrhythmia. ScienceDaily. Retrieved December 4, 2024 from www.sciencedaily.com/releases/2005/11/051114215823.htm
Johns Hopkins Medical Institutions. "Heart Mapping Technique Safely Guides Catheter Repair Of Arrhythmia." ScienceDaily. www.sciencedaily.com/releases/2005/11/051114215823.htm (accessed December 4, 2024).

Explore More

from ScienceDaily

RELATED STORIES